Levelmount_Machine_Mounts

ADS/SLM ISR-System SLM-ISR type ADS-ISR type ISR Control Unit Overview of programmable parameters • Reset accuracy: rough (+/- 0.5 mm, fine (+/- 0.1 mm), user-defined (+/- 0.01 mm ... 1 mm) • Permissible deflection: wide (+/- 1.0 mm), narrow (+/- 0.5 mm), user-defined (+/- 0.01 mm ... 1.5 mm) • Response time: fast (10 ms), slow (125 ms), user-defined (5 ms ... 125 ms) • Level: Middle position (+/- 5 mm), fine adjustment with potentiometer and / or software ADS-/SLM-ISR Series Dimension table Dimensions in mm D Ho Ni A Load (max.) kN ADS 3 105 65 +/- 5 106 1.8 ADS 6 127 90 +/- 6 130 2.8 ADS 12 / SLM 12 B ISR 175 / 170 90 +/- 6 175 6.0 ADS 24 245 90 +/- 6 255 13.0 ADS 48 338 90 +/- 6 343 26.0 ADS 96 468 90 +/- 6 470 55.0 ADS 192 610 90 +/- 6 610 100.0 180 40 130 15 ISR system The basic version of the ISR pneumatic spring system is factory-programmed. However, the software allows varying the following parameters: reset accuracy, permissible deflection, response time, average level. These parameters can be viewed, freely chosen within wide limits, and permanently stored in the control unit. The values are retained even after a power failure. The factory default settings are documented in a datasheet. D A A H 0 Ni D A A H 0 Ni