Hygienic_Design

Page 29 | Highlights - Standard Parts in Hygienic Design Leveling feet GN 19 comply with the 3-A sanitary standard 88-01 and the DGUV testing principles, making them suitable for use in hygienic areas. The elastomer pad seals the space below the foot plate against dirt. This is achieved by the weight of the machine on the plate. The sealing ring above the adjustment sleeve enables fastening without dead space. Due to the wiper and the joint sealing ring, the moving components are sealed against the environment. The high quality finish prevents adherence of dirt and facilitates cleaning. The values listed in the table for static load capacity refer to a purely vertical load in relation to the leveling foot. Under normal operating con- ditions bending loads or angular loads are not uncommon and result in a reduction of load capacity, which must be taken into consideration. see also... • Leveling Feet GN 20 (Stainless Steel, Hygienic Design ) Page 30 / 32 Information • Spindle, adjustable sleeve - Stainless steel AISI 304 - Turned • Foot plate Stainless steel sheet metal AISI 316L • Seals, blue, FDA compliant - Sealing ring H-NBR, hardness 70 ±5 Shore A - Wiper TPU, hardness 95 ±5 Shore A - Joint sealing ring H-NBR, hardness 85 ±5 Shore A • Elastomer pad, blue, FDA compliant - Silicone, hardness 85 ±5 Shore A - Vulcanised • 3-A Principles Page 6 • Elastomer Characteristics Page 38 • Stainless Steel Characteristics Page 39 • RoHS Specification • Cover Sleeves GN 20.1 Page 34 • Sealing RIngs GN 7600 Page 36 • Wipers GN 7607 Page 37 Accessory 1 d 1 2 d 2 3 l 1 4 Type 1 2 3 4 GN19-100-M16-175-A GN 19 Leveling Feet continued Sealing concept How to order

RkJQdWJsaXNoZXIy MTQ2MTM=